Saha nesnesi kuralları kataloğu — Almanya
Bir yapı veya altyapı nesnesi seçin ve planlama pasaportunu kontrol edin: sınır mesafeleri, sıhhi mesafeler, yangın güvenliği alanları ve kaynak bağlantıları.
Gösteriliyor 14
Müştemilat
Bahçe kulübesi
Auxiliary · depends on foundation
- İzin Varies by state (e.g. BW 40 m³, Bavaria 75 m³, NRW 30 m²) — check locally
- Standard setback to boundary Typically about 3 m (depth = factor × wall height; factor varies by state)
- Small building on the boundary BW: non-habitable, wall ≤3 m and ≤25 m² wall area, ≤9 m per boundary, 15 m total
Bahçe yapısı
Sera
Auxiliary · usually lightweight
- İzin Yerel imar yönetmeliğini kontrol edin
- Setback to boundary Typically about 3 m (depth = factor × wall height; factor varies by state)
- Greenhouse on the boundary (BW) Wall ≤3 m, wall area ≤25 m²; agricultural greenhouses keep ≥1 m
- Roof overhang / runoff Overhangs up to 50 cm usually ignored in the setback; keep runoff on your plot
Bahçe yapısı
Swimming pool
Auxiliary · usually permanent
- İzin Yerel imar yönetmeliğini kontrol edin
- Local code check Use the local municipality / emirate / county requirements before final placement.
Banyo ve duş
Banyo evi / sauna
Auxiliary · usually permanent
- İzin Yerel imar yönetmeliğini kontrol edin
- Setback to boundary Typically about 3 m (depth = factor × wall height; factor varies by state)
- Boundary privilege excluded A garden building with fireplace/habitable space cannot sit in the required setback zone
- Wood-fired stove Chimney/fire-safety approval required — confirm with chimney sweep & local authority
Müştemilat
Garaj
Auxiliary · usually permanent
- İzin Yerel imar yönetmeliğini kontrol edin
- Garage on the boundary Allowed: wall ≤3 m, ≤9 m per boundary, 15 m total
- Otherwise standard setback Depth = factor × wall height (factor 0.4–1 by state), typically about 3 m
- Exclusions No habitable rooms; double/large/RV garages lose the boundary privilege
Müştemilat
Sundurma / Kanopi
Auxiliary · usually lightweight
- İzin Yerel imar yönetmeliğini kontrol edin
- Carport on the boundary Allowed: wall ≤3 m, ≤9 m per boundary, 15 m total
- Roof overhang / runoff Overhangs up to 50 cm usually ignored; keep runoff on your own plot
- If oversized Standard setback: depth = factor × wall height, typically about 3 m
Banyo ve duş
Dış mekan duşu
Auxiliary · usually lightweight
- İzin Yerel imar yönetmeliğini kontrol edin
- Greywater drainage Subject to water law — do not just soak into soil; check municipal rules
- Setback to boundary Follow accessory-building rules: ~3 m unless small/privileged
Hayvan barınağı
Kümes / tavşan kümesi
Auxiliary · depends on foundation
- İzin Yerel imar yönetmeliğini kontrol edin
- Setback to boundary Often about 3 m, but varies strongly by state/municipality
- Distance to wells & neighbour windows Set by state code / municipality — confirm with the building authority
Sıhhi tesis
Dış mekan tuvaleti
Auxiliary · usually lightweight
- İzin Yerel imar yönetmeliğini kontrol edin
- Distance to drinking-water well At least 50 m to a drinking-water source
- Distance to boundary At least 2 m for installation parts
- Sanitary rules Per water law / DIN 4261 — confirm with local authority
Sıhhi tesis
Septik tank / arıtma ünitesi
Auxiliary · usually permanent
- İzin Yerel imar yönetmeliğini kontrol edin
- Distance to drinking-water well At least 50 m
- Distance to dwelling At least 5 m
- Distance to boundary At least 2 m
Su kaynağı
Kuyu / sondaj
Auxiliary · depends on foundation
- İzin Subject to water law — notify/permit with local authority
- Protection distance to wastewater At least 50 m to septic/seepage/sewer/toilet
Kompost alanı
Kompost kutusu
Auxiliary · usually lightweight
- İzin Yerel imar yönetmeliğini kontrol edin
- Distance to drinking-water well Stay clear of the 50 m well protection distance
- Odour / runoff to boundary Set by state neighbour law / municipality — verify locally
Açık ateş alanı
Barbekü ızgarası / mangal
Auxiliary · usually lightweight
- İzin Yerel imar yönetmeliğini kontrol edin
- Distance to non-combustible buildings At least 5 m (large grills); 3 m for small grills
- Distance to tents / timber buildings At least 10 m (large grills); 5 m for small grills
Açık ateş alanı
Ateş çukuru
Auxiliary · usually lightweight
- İzin Yerel imar yönetmeliğini kontrol edin
- Distance to buildings At least 50 m to buildings/trees/reeds and other combustibles
- Distance to forest Permit required within 100 m of forest (§19 Landeswaldgesetz)
- Small fire bowl alternative Pile height/diameter ≤1 m, only dry aged (≥2 yr) untreated wood or briquettes